Antminer ERROR_TEMP_TOO_HIGH: what does it mean?

Antminer showing ERROR_TEMP_TOO_HIGH in the kernel log? Understand the symptoms, possible causes, and when to send it for professional technical analysis.

By LDM Brasil Repair ·

If your Antminer is showing the ERROR_TEMP_TOO_HIGH error in the kernel log, it means one of the hashboards detected a temperature above the safe operating limit.

This error can appear on models such as the Antminer S19j Pro, S19, S19 Pro, S19k Pro, S21, and other Bitmain ASICs. When it happens, the machine may reduce its performance, shut down a hashboard, or stop mining entirely to prevent damage.

Common symptoms

When the ERROR_TEMP_TOO_HIGH error appears, the miner may notice:

  • Zero hashrate or below-normal hashrate;
  • One hashboard stopping;
  • Fans running at maximum speed;
  • The machine shutting down mining;
  • A temperature error in the kernel log;
  • Frequent restarts;
  • The board not reading temperature correctly;
  • The machine running for a few minutes and then stopping.

This issue can be caused either by genuinely elevated temperature or by a failure in the hashboard's sensor readings.

Possible causes of the error

The most common causes are:

  • An overly hot environment;
  • Poor air circulation;
  • Excess dust;
  • Weak or defective fans;
  • Hot exhaust air recirculating back into the machine's intake;
  • Dried out or poorly applied thermal paste;
  • A heatsink with poor contact;
  • A defective temperature sensor;
  • Oxidation on the hashboard;
  • Humidity;
  • A problem with the board's temperature reading.

In some cases, the machine is genuinely running too hot. In others, the error may be related to sensors, oxidation, or an internal hashboard failure.

What to check before sending for analysis?

Before seeking assistance, the miner can perform a few basic checks:

  • Copy the machine's kernel log;
  • Check whether the fans are spinning properly;
  • Check for excess dust at the air intake or exhaust;
  • Improve the room's ventilation;
  • Make sure hot air isn't recirculating back into the machine's intake;
  • Check whether the error always appears on the same hashboard;
  • Revert to default settings if using overclock.

This information helps determine whether the issue is caused by the environment or by a failure in the hashboard itself.

When to seek professional technical analysis?

If the ERROR_TEMP_TOO_HIGH error keeps appearing even with good ventilation, working fans, and a controlled environment, the best option is to send the machine or hashboard for a professional technical analysis.

This error can involve a failed temperature sensor, oxidation, poor thermal contact, or an internal problem on the board.

LDM Brasil Repair performs technical analysis and repair of Antminer hashboards. If your machine is showing a temperature error, send the kernel log for an initial evaluation.

Conclusion

The ERROR_TEMP_TOO_HIGH error indicates that the Antminer detected a temperature above the safe limit or a failure in the hashboard's thermal reading.

The customer can check ventilation, fans, dust, environment, and the kernel log. However, if the error persists, it's recommended to seek professional technical analysis.

Contact LDM Brasil Repair and send your Antminer's kernel log for evaluation.