When an Antminer shows a Nonce CRC error in the kernel log, it's common for the machine to power on normally, load the dashboard, connect to the network, and even complete part of the boot process — yet one or more hashboards fail to start mining properly.
This issue can appear on models like the Antminer S19, S19 Pro, S19j Pro, S19k Pro, S21, T21, and other Bitmain ASIC machines.
In practice, the miner may notice symptoms such as zero hashrate, a stalled hashboard, a chain error, unstable mining, or repeated messages in the kernel log.
In this article, you'll learn what the Nonce CRC error means, which basic checks a miner can safely perform, and when the problem requires professional bench diagnosis.
What does the Nonce CRC error mean on an Antminer?
The term nonce relates to the mining process carried out by the ASIC chips on the hashboard. During mining, the chips process calculations and return results to the control board.
When Nonce CRC error shows up in the kernel log, it indicates a failure in the validation or communication of that data. In simple terms, the machine received a response that was incorrect, corrupted, or outside the expected pattern.
This error usually points to a problem in hashboard communication, the ASIC chips, internal board signals, or failures caused by poor contact, overheating, cold solder joints, oxidation, or unstable power delivery.
The error doesn't always mean the hashboard is a total loss. However, when it persists, it's a sign the machine needs attention.
Common symptoms of the Nonce CRC error
The Nonce CRC error can show up in different ways on the Antminer. The most common symptoms are:
- Hashboard doesn't start mining;
- Machine powers on but stays at zero hashrate;
- A chain shows an error;
- One of the boards isn't working correctly;
- Kernel log shows repeated error messages;
- Machine tries to start and keeps restarting the process;
- Hashrate becomes unstable;
- Machine runs fine for a few minutes and then loses performance;
- Chips are detected but the board doesn't mine stably;
- Fans spin up and the machine never stabilizes.
This error shouldn't be confused with a simple pool or internet issue. If the network and pool are correctly configured but the kernel log keeps showing nonce crc error, the failure is likely related to the hashboard.
Main causes of the Nonce CRC error
The Nonce CRC error can have several causes. The most common include:
- Flat cable with poor contact;
- Oxidized or loosely seated connector;
- Control board with a communication fault;
- Incompatible or corrupted firmware;
- Aggressive overclock;
- Poorly configured undervolt;
- Machine overheating;
- Power supply with unstable output;
- Hashboard with dirt or oxidation;
- Cold solder joint on an ASIC chip;
- Faulty ASIC chip;
- Abnormal internal signal on the hashboard;
- Previous repair done poorly;
- Broken trace or altered component on the board.
That's why correct diagnosis matters. Swapping parts on a guess can create unnecessary costs without fixing the actual problem.
What can the miner check before sending it in for repair?
Before opening a support ticket or sending the hashboard in for service, there are a few basic checks a miner can safely perform without opening the board or touching sensitive points. These tests help rule out simple issues.
1. Copy and save the kernel log
The first step is to access the Antminer dashboard and copy the kernel log. The kernel log is one of the most important pieces of information for an initial analysis, since it shows error messages that help identify whether the fault is related to a chip, chain, sensor, firmware, power supply, communication, or hashboard.
Look for messages like:
nonce crc errorchain errorasic errorfind 0 asichashboard missingCRC errorPIC errortemp sensor errorfailed to inithardware error
When contacting LDM Brasil Repair, send the kernel log along with the machine model and a description of the issue.
2. Restart the machine properly
Fully power off the Antminer, wait a few minutes, and turn it back on. In some cases, a temporary boot failure can disappear after restarting the machine.
However, if the error keeps coming back, it's not recommended to keep trying repeatedly. If there's a short circuit, a degraded chip, an unstable power supply, or an internal hashboard fault, repeatedly powering the machine on can make the problem worse.
3. Check the pool, internet, and basic configuration
Before suspecting the hashboard, confirm that the machine's basic configuration is correct:
- Whether the pool is correct;
- Whether the worker field is filled in correctly;
- Whether the internet connection is stable;
- Whether the network cable is working;
- Whether the machine shows online on the network;
- Whether the installed firmware is compatible with the model;
- Whether the error started after an update or configuration change.
If the machine can't connect to the pool, it could be a network or configuration issue. But if the pool is correctly set and the Nonce CRC error still appears in the kernel log, the fault is more likely tied to hardware.
4. Revert to a safe configuration
If the Antminer is running overclock, undervolt, or custom firmware, revert to a safer configuration and test again.
Aggressive overclocking can raise temperature, put more strain on the ASIC chips, and make hashboard communication unstable. Over time, this can cause errors, hashrate loss, and chip degradation.
5. Check flat cables with the machine powered off
With the machine fully unplugged, visually inspect the flat cables connecting the control board to the hashboards. Look for:
- Loose cable;
- Bent cable;
- Folded cable;
- Poorly seated connector;
- Oxidation;
- Bent pin;
- Visibly damaged cable.
If you have some basic experience, you can swap the cables between hashboards to see if the error moves position. However, this should only be done with the machine unplugged from power.
Never remove or connect cables while the Antminer is powered on.
6. Check temperature and airflow
High temperature is one of the biggest enemies of hashboards. If the machine operates in a very hot environment, with dust, trapped air, or poor airflow, the chips can fail more easily.
Check whether the fans are working, whether the air intake is clear, whether hot exhaust air isn't recirculating back into the machine, whether there's excessive dust, and whether temperature rises too quickly.
What shouldn't the customer do?
Some procedures aren't recommended for the average miner, since they require technical knowledge and specific equipment. Avoid:
- Opening the hashboard without experience;
- Measuring internal board signals;
- Heating chips with a hot air gun;
- Resoldering components without a diagnosis;
- Washing the board without knowing the cause of the problem;
- Applying flux or paste to random components;
- Replacing a chip without testing;
- Touching the board while it's powered;
- Forcing connectors;
- Continuing to power on the machine if there's a burning smell, short circuit, or abnormal heating.
Many hashboard faults are recoverable when caught early for analysis. However, repair attempts without proper equipment can turn a simple defect into a much costlier problem.
When does the Nonce CRC error require bench diagnosis?
The machine should be analyzed on a bench when:
- The error persists after restarting;
- The pool and internet are correctly configured;
- The firmware is appropriate;
- The configuration has been set to safe mode;
- The flat cables have been checked;
- The error always appears on the same chain;
- A hashboard fails to start;
- The machine stays at zero hashrate;
- The board runs briefly and then fails;
- The kernel log shows a recurring error;
- The machine has already been through a previous repair;
- There's a suspicion of a chip issue, cold solder joint, oxidation, or short circuit.
Fixture testing: done on the bench by LDM
Fixture testing isn't a procedure for the end customer. The fixture is a bench tool used to test the hashboard outside of the machine. With it, the technician can check chip communication, analyze the board's behavior, and identify possible internal failures.
This test helps determine whether the problem lies in an ASIC chip, communication between chips, a specific region of the hashboard, a boot failure, an abnormal internal signal, board power delivery, or a defect caused by a cold solder joint, oxidation, or an altered component.
RI signal analysis: why isn't it a customer test?
The RI signal is an important communication line between the ASIC chips on the hashboard. When this signal is altered, the board can show errors such as nonce crc error, chain errors, a hashboard that fails to start, find 0 asic, chips detected with a fault, or hashrate instability.
Analyzing the RI signal requires opening the hashboard and measuring specific points on the board. This procedure requires technical knowledge, proper tools, and experience interpreting the signals.
That's why customers shouldn't try to measure RI at home. A wrong contact point, an accidental bridge, or a measurement taken at the wrong point can cause further damage to the hashboard.
Can a faulty ASIC chip cause Nonce CRC?
Yes. A defective ASIC chip, a cold solder joint, or abnormal communication can cause a Nonce CRC error. In some cases, the hashboard even initializes but can't mine stably. In others, the board shows an error right at startup and doesn't work at all.
When the problem is in a specific chip, it may be necessary to locate the faulty chip, perform a visual inspection, test signals, remove the chip, clean the area, replace the chip, reapply thermal paste correctly, and test the board again.
This procedure requires a rework station, a microscope, BGA soldering experience, and specific knowledge of ASIC hashboards.
Can Nonce CRC be caused by overclocking?
Yes. Overclocking can be one of the causes or a factor that accelerates the problem. When the machine runs at high frequency, inadequate voltage, or elevated temperature, the ASIC chips suffer more strain. Over time, this can cause instability, communication errors, and degradation.
If the Nonce CRC error started after overclocking, the best approach is to stop the machine, revert to a safe configuration, and send the log for analysis.
Can Nonce CRC be a power supply issue?
It can. A power supply with unstable output can cause abnormal hashboard behavior. Symptoms that may point to the power supply include: the machine restarting, hashrate fluctuating, errors on more than one hashboard, failures when consumption increases, the power supply overheating, boards stopping randomly, and different errors happening at different times.
Can Nonce CRC be a control board issue?
Yes, although it's not always the main cause. The control board is responsible for communicating with the hashboards. If there's a fault in the control board, a defective port, or an issue with the communication cables, the machine can show errors related to reading the boards.
That's why, before writing off a hashboard, it's important to assess whether the error follows the board, the cable, or the control board port.
Why shouldn't you replace parts on a guess?
A common mistake is trying to solve the problem by buying a new cable, power supply, control board, or even another hashboard without a diagnosis. This can lead to losses, because the Nonce CRC error can have many causes: flat cable, control board, power supply, firmware, configuration, ASIC chip, RI signal, cold solder joint, oxidation, power circuit, or a previous repair.
Without a diagnosis, the customer may spend money and still end up with a machine that's down.
How does LDM Brasil Repair diagnose the Nonce CRC error?
At LDM Brasil Repair, diagnosis is carried out in a technical, organized way. The analysis can include:
- Reading the kernel log;
- Reviewing the fault history;
- Checking the machine model;
- Testing each hashboard individually;
- Fixture testing;
- Visual inspection of the board;
- Signal analysis;
- RI signal verification;
- Power supply verification;
- Sensor analysis;
- ASIC chip testing;
- Oxidation inspection;
- Cold solder joint assessment;
- Final hashboard test after repair.
The goal is to find the real cause of the error and avoid unnecessary part replacement.
When should you send the hashboard to LDM?
Contact LDM Brasil Repair when your Antminer shows a Nonce CRC error, a hashboard that won't start, zero hashrate, a chain error, find 0 asic, an ASIC error, failing chips, an unstable machine, a hashboard disappearing from the dashboard, a machine that keeps restarting, an error after overclocking, a board that has already been through a previous repair, or a suspicion of a short circuit, oxidation, or overheating.
When reaching out, send: the machine model, the kernel log, a photo of the dashboard (if possible), the fault history, whether you're using stock or custom firmware, whether the machine was overclocked, and whether the problem started after a power outage, cleaning, transport, or maintenance.
Frequently asked questions about Nonce CRC on the Antminer
Does the Nonce CRC error mean the hashboard is burned out?
Not necessarily. It could be a communication issue, a cable, firmware, power supply, control board, ASIC chip, or an internal board signal. A proper diagnosis is needed to confirm.
Can I keep mining with this error?
It's not recommended to keep insisting if the error persists. If there's a short circuit, overheating, a degraded chip, or unstable power, continuing to power the machine on can make the fault worse.
Can the customer test RI at home?
No. Analyzing the RI signal requires opening the hashboard, using proper tools, and knowing how to interpret the signals. This procedure must be done on a technical bench.
Is fixture testing mandatory?
In many cases, yes. When the error is related to the hashboard, the fixture helps identify internal failures that don't show up by just looking at the machine's dashboard.
Can overclocking cause this error?
Yes. Overclocking, high temperature, and inadequate voltage can cause instability and accelerate ASIC chip degradation.
Is it worth repairing a hashboard with Nonce CRC?
In most cases, yes, it's worth getting a diagnosis. Many boards can be recovered once the fault is correctly located.
Conclusion
The Nonce CRC error in the Antminer's kernel log generally indicates a communication failure or an invalid response coming from the hashboard. The problem could be something simple, like a flat cable or configuration issue, but it could also point to an ASIC chip failure, an abnormal RI signal, a cold solder joint, oxidation, or a power delivery issue.
The customer can check the kernel log, pool, firmware, configuration, external cables, and temperature. However, tests like fixture testing, RI signal analysis, and chip repair should only be performed on a technical bench.
If your Antminer is showing a nonce crc error, zero hashrate, a hashboard that won't start, or a chain error, contact LDM Brasil Repair and send the kernel log for an initial analysis.