When an Antminer stops mining, every hour is money lost. Before you start taking it apart or throw it away, run this basic diagnostic — 80% of cases fall into one of the 7 causes below.
1. Faulty hashboard
Symptoms: hashrate drops by half or a third, log shows "chain X missing" or missing chips.
Common cause: burnt chip, cold solder joint, altered LDO.
What to do: check the logs to see which chain has the problem. If it's an entire chain, it's usually a chip or power issue. This type of repair requires a workbench with a BGA rework station.
2. Faulty PSU
Symptoms: the machine won't turn on, turns on and off by itself, unstable hashrate.
Cause: aged capacitors, power surge, overload.
Test: measure the output voltage with a multimeter (it should be close to 14.5V on the S19/S21). If it's off, replace the PSU.
3. Overheating
Symptoms: the machine restarts on its own after a few minutes, logs show "temp too high."
Causes:
- Dried thermal paste
- Faulty fans
- Clogged air filter
- High ambient temperature
What to do: clean the machine, check that all 4 fans are spinning, replace thermal paste on the chips if needed.
4. Network issue
Symptoms: dashboard unreachable, no hashrate showing on the pool.
Test: ping the machine's IP. Check the cable, switch, and pool configuration.
5. Corrupted firmware
Symptoms: the machine powers on but doesn't boot, gets stuck in a loop, zero hashrate.
Solution: recovery via SD card or reflash via Toolkit. See the VNISH guide.
6. Faulty control board
Symptoms: fans spin, but there's no communication, no hashboard responds.
Diagnosis: swap in a known-good control board. If the machine comes back to life, that was the culprit.
7. Hashboard communication failure (BO/BI/CI/CO)
Symptoms: detects fewer chips than it should, incomplete chain.
Cause: coupling resistors, damaged level shifters (common on the S19).
When to call a specialist
If the problem involves the hashboard, BGA soldering, chip replacement, or advanced signal diagnostics, it's time for a lab. LDM Brasil Repair serves all of Brazil — you ship it via mail and receive a quote within 48 hours after analysis.