An Antminer that's powered on and connected to the internet isn't necessarily working as expected.
To know whether the miner is operating normally, the owner should keep track of a few basic pieces of information about the equipment.
You don't need to run an electronic diagnosis to notice the main signs of abnormal operation.
1. Compare the hashrate
The first indicator is hashrate.
Compare the performance shown by the machine with what's expected for the model and configuration in use.
Small fluctuations can happen, but a large, persistent difference deserves attention.
2. Check the hashboards
Check whether all the expected hashboards are showing up on the panel.
An Antminer can keep mining even after losing a board.
In that case, total hashrate usually drops significantly.
3. Check individual board performance
When the interface shows separate information for each hashboard, compare their behavior.
A large, recurring difference can indicate that one of the boards isn't working as it should.
4. Monitor the temperature
ASIC miners generate a lot of heat.
So check whether temperatures stay within normal behavior for that installation, and whether there are abnormal differences between boards.
High temperature can also be a consequence of the environment.
5. Check the fans
The fans need to maintain the airflow required for cooling.
Different noise, a stopped fan, or abnormal behavior deserves attention.
6. Monitor the pool
Besides the Antminer's interface, check whether the worker is connected to the pool and delivering hashrate.
Temporary differences can occur, so it's best to look at an average rather than just one isolated moment.
7. Watch for rejections and stability
A machine can be producing hashrate and still show unstable behavior.
Frequent drops, reboots, and disconnections deserve investigation.
8. Check for error messages
The system logs information about the miner's startup and operation.
When the machine has a problem, these messages can help identify which area is affected.
9. See if the problem only happens after some time
Some faults only show up once the machine heats up.
So an Antminer that works fine in the first few minutes shouldn't be considered stable for that reason alone.
When should you seek a diagnosis?
Some signs that deserve attention are:
- a hashboard has disappeared;
- hashrate dropped significantly;
- the machine shows 0 TH/s;
- frequent reboots;
- an incorrect number of ASICs;
- temperature errors;
- intermittent operation.
If these problems persist, the equipment may need to be diagnosed.
Need help?
LDM Brasil Repair performs diagnosis and repair of Antminer hashboards.
Send the machine model, a photo of the panel, and the Kernel Log, when available, via WhatsApp.